GPS-3200 series

LCR Meter

GPS-3200 Series Precision Benchtop LCR Meters

10 Hz to 1 MHz, continuous · ±0.05% basic · six and a half digits

A component behaves differently at every frequency, and a bench bridge is what lets you go and look. The frequency is continuous rather than a short list, the drive is held where you set it, and a bias can be put across the part while you measure. Five models, separated only by how far up they reach.

Download Datasheet

Nine-bin comparator with counting · ten-point list sweep · open, short and load correction · LAN, GPIB, RS232, USB and Handler

GPS LTD GPS-3205 benchtop LCR meter seen from the front and side, showing the colour display with the measurement settings above a capacitance and dissipation reading, the numeric keypad, and the four BNC test terminals marked H pot, H sense, L sense and L pot beside the guard terminal
GPS-3205 shown · 330 × 285 × 136 mm, 3.6 kg

Three things you cannot do with a handheld

A handheld tells you what a part measures. A bench bridge lets you decide the conditions first, which is the whole of component characterisation.

Frequency you choose, not frequency you are given

Continuously adjustable from 10 Hz in steps of 1 mHz, up to 1 MHz on the top model. A handheld gives you five or six fixed points. This gives you the one the part will actually see, and a ten-point sweep to find where it stops behaving.

10 Hz to 1 MHz
Resolution 1 mHz, accuracy ±0.01%

A drive that stays where you put it

Set the level as a voltage from 10 mV to 2 V or as a current from 100 µA to 20 mA, and automatic level control holds it there as the load changes. Source impedance is selectable, which is what makes an inductor reading comparable with a figure taken on another instrument.

30 Ω or 100 Ω source
Level control to ±(2% + 2 mV)

Bias, for the parts that need it

Electrolytics and varactors do not behave the same way with a working voltage across them as they do at zero. Bias runs to ±2 V and ±20 mA from inside the instrument, and to ±60 V from an external supply at the rear.

±2 V and ±20 mA internal
To ±60 V from an external supply

Nine impedance ranges from 30 Ω to 300 kΩ sit under all of it, automatic or held, and holding the range is what speeds a long batch up.

Five models, one instrument

Everything below is common to all five. What separates them is the top of the frequency range, and the two smaller ones differ in a couple of details worth knowing before you order.

ModelFrequency rangeFast measurementGPIBOrder code
GPS-320110 Hz to 100 kHz20 readings/sOptional503201
GPS-320210 Hz to 200 kHz50 readings/sFitted503202
GPS-320310 Hz to 300 kHz50 readings/sFitted503203
GPS-320510 Hz to 500 kHz50 readings/sFitted503205
GPS-321010 Hz to 1 MHz50 readings/sFitted503210

The lead-type Kelvin fixture is supplied with the GPS-3203, 3205 and 3210. All five come with the four-terminal Kelvin cable and the short circuit bar.

Measurement display range

Two parameters are taken in the same cycle, in any of twenty pairings, and either can be left for the instrument to choose.

ParameterDisplay rangeMeasured as
Capacitance0.001000 pF to 99.9999 FCp or Cs
Inductance0.001000 nH to 99.9999 kHLp or Ls
Resistance, reactance and impedance0.001000 mΩ to 999.999 MΩRp, Rs, Xs and |Z|
Conductance, susceptance and admittance0.001000 µS to 999.999 kSG, B and |Y|
Dissipation and quality±0.000001 to 9.99999 · ±0.001 to 99999.9D and Q
Phase angle±179.9999° or ±3.14159 radθd or θr

±0.05% is the best case. It applies on the slow or medium rate, between 30 Hz and 10 kHz, from 10 Ω to 100 kΩ, at a drive between 0.5 V and 1.5 V, with correction run and ranging automatic. Outside that the accuracy tables in the datasheet give the figure that applies.

Sorting a reel, not a part

Both of these exist because the instrument is expected to sit on a line rather than a bench, making the same decision thousands of times without anyone reading the screen.

Comparator

Nine bins, and a count of each

  1. Set limits as absolute values, as a deviation from a nominal, or as a percentage of it.
  2. Parts fall into one of nine bins, an out-of-bin, or an auxiliary bin when the main parameter passes and the second one does not.
  3. Each bin counts to 999999, and the Handler interface drives the machine that does the sorting.
List sweep

Ten points, one trigger

A sweep runs up to ten points of frequency, drive level or bias, each with its own upper and lower limit. In sequential mode one trigger sweeps the lot and reports at the end; in stepping mode each trigger advances one point. It is the difference between knowing a capacitor is in tolerance at 1 kHz and knowing it is in tolerance across the band it will work in.

Triggering can be internal, from the front panel, from the handler or over the bus, with a delay of up to ten seconds to let a part settle on the contacts before the reading is taken.

Technical specifications

Common to all five models except where a model is named. Frequency, drive level and bias are all set on the instrument and shown with the reading.
MeasuresTwenty parameter pairings · main from Cp, Cs, Lp, Ls, Rs, |Z|, |Y| and G · second from D, Q, G, B, Rp, Rs, Xs and phase angle in degrees or radians
Basic accuracy±0.05% · six and a half digit resolution
Test frequency10 Hz to 1 MHz, model dependent · 1 mHz resolution · ±0.01% accuracy
Test levelVoltage 10 mVrms to 2 Vrms at ±(5% + 5 mV) · current 100 µArms to 20 mArms at ±(5% + 50 µA) · automatic level control
Source impedance30 Ω or 100 Ω, selected on the instrument
DC biasInternal −2 V to +2 V at ±(2% + 5 mV), and −20 mA to +20 mA · external −60 V to +60 V
RangingNine impedance ranges, 30 Ω, 100 Ω, 300 Ω, 1 kΩ, 3 kΩ, 10 kΩ, 30 kΩ, 100 kΩ and 300 kΩ · automatic or held
Measurement rateSlow 1.25, medium 10 and fast 50 readings per second · custom from 0.5 to 200 · fast is 20 readings per second on the GPS-3201
CorrectionOpen, short and load · open and short interpolated across 49 fixed frequency points, or taken at a chosen point · cable length 0, 1, 2 or 4 m · self-calibration
TriggerInternal, manual, external or bus · delay 0 to 10 s in 1 ms steps
Display7 in TFT, 800 × 480 · English interface · 32 backlight steps · dual parameter reading
Interfaces and storageLAN, RS232, GPIB, USB device, USB host and Handler · ten setups internally and ten on USB · readings as CSV and screens as image files
Power and size220 V AC ±10%, 45 to 55 Hz, 110 V optional · under 20 W · 330 × 285 × 136 mm · 3.6 kg
EnvironmentOperating 0 to 40 °C · humidity 15% to 85% · altitude to 2000 m · 30 minutes warming, up to 16 hours continuous

What’s in the box

  • GPS-3200 series meter
  • Four-terminal Kelvin test cable
  • Lead-type Kelvin test fixture, GPS-3203, 3205 and 3210
  • Gold-plated short circuit bar
  • Three-core power cord
  • Instruction manual and warranty certificate

Fixtures and leads

Available separately: GPIB, RS232 and USB leads, 2 m and 4 m test cables, an SMD component fixture, an LCR test pen with a four-wire surface mount fixture, and a Kelvin fixture. Cable length is compensated in the instrument at 0, 1, 2 or 4 m, so a longer lead does not cost you the correction.

Request a quote — GPS-3200 series

We’ll reply with pricing, lead time and options.

Request a calibration certificate

Send us the serial number and we’ll locate your certificate.

General enquiry

Ask us anything — sales, technical, or order related.

Request a Quote

We’ll reply with pricing, lead time and options.

We never share your details. By sending, you agree to be contacted about your enquiry.