Substation & HV Asset Diagnostics

TD-6900 Automatic Capacitance and Tan Delta Tester

Tan delta and capacitance of transformers, bushings, CVTs, capacitors and arresters, measured either side of the mains frequency so interference from live plant stays out of the result.

0.5 to 10 kV Tan δ ±(1.5% + 0.06%) UST · GST · CVT
Download Datasheet

Part number 806900 · replaces the GPS-6800 · 35 kg

TD-6900 tan delta tester, top panel TD-6900 tan delta tester in its case with the lid open

10 kV built in

0.5 to 10 kV in 500 V steps from a 1500 VA source.

0.001% resolution

Tan δ to 0.001% and capacitance to 0.001 pF.

45/55 Hz measurement

Mains interference from live plant filtered out.

C1 and C2 in one test

CVT self-excitation, no 10 kV needed.

Applications

Where it’s used

Tan delta shows moisture, ageing and local defects in insulation before they show anywhere else.

Transformers and bushings

Winding insulation and bushing test taps, at commissioning and in preventive testing.

Instrument transformers and CVTs

CTs and PTs, and CVT C1 and C2 by self-excitation, including on an earthed bus.

Capacitors, reactors and arresters

Capacitance and loss together, with inductive and resistive objects recognised automatically.

Workshops and laboratories

Insulating oil with an oil cup, solid materials with an electrode, and verification against a standard.

Measuring beside live plant

Step around the interference

40455055606570HzInterference from live plant45 Hz55 Hz50 Hz result calculated

Measure at 45 and 55 Hz, report 50 Hz

In a substation the 50 Hz field from energised equipment can swamp a test current of a few milliamps. In the 50D mode the TD-6900 measures at 45 Hz and 55 Hz, where its filtering passes only the test signal, and calculates the 50 Hz result.

Near power frequency tan δ changes steadily with frequency, so the two readings are close and the result stands for a 50 Hz test. The 60D mode does the same at 55 and 65 Hz for 60 Hz systems.

On a generator? Its frequency drifts, so select a fixed frequency instead and the drift drops out of the measurement.
Connections

Four ways to connect

The same four connections are printed on the instrument’s panel.

Positive connection

Ungrounded test object

Test current is measured at the low-voltage end of the test object through C4, so the reading excludes stray paths to earth. The usual choice for transformer bushings with a test tap, capacitors and CTs on the bench.

UST Side of case HV OUTPUT TD-6900 C3 Cn(C2) C4 Cx(C1) CVT1 CVT2 Cx HV core: big red clip HV shield: small black clip Cx core: red clip Cx shield: black clip to LV shield, or free
Reverse connection

Grounded test object

For equipment that cannot be lifted from earth. The test current returns through the HV lead itself, and its shield clip can guard out a branch that should not be measured.

GST Side of case HV OUTPUT TD-6900 C3 Cn(C2) C4 Cx(C1) CVT1 CVT2 Cx HV core: big red clip HV shield: black clip, or free Cx input not used
C1 and C2 in one test

CVT self-excitation

CVT1 and CVT2 drive a secondary winding at low voltage and the CVT generates its own test voltage. One connection gives C1 and C2 with their tan δ, and no 10 kV leaves the instrument. Where the bus must stay earthed, the GSTg mode measures the top section by reverse connection with low-voltage shielding.

CVT self-excitation Side of case HV OUTPUT TD-6900 C3 Cn(C2) C4 Cx(C1) CVT1 CVT2 C1 C2 A δ, earth link removed X a1 n1 a2 n2 da dn HV core to the δ end of C2 Cx core to the top of C1 or any secondary
Beyond 10 kV

External HV and standard capacitor

Pair the TD-6900 with an external high-voltage supply and standard capacitor, including a series resonant set. The instrument tracks the supply from 40 to 70 Hz and reads Cx and Cn through C4 and C3.

External high voltage, external standard capacitor Side of case HV OUTPUT TD-6900 C3 Cn(C2) C4 Cx(C1) CVT1 CVT2 External HV supply Cx Cn Cx lead to C4 Cx(C1) Cn lead to C3 Cn(C2) HV OUTPUT not used
Product Features

Built for site work

Layered protection

The output cuts off on a high-voltage short or breakdown, a poor earth trips the earth protection, and CVT tests run inside four voltage and current limits. On large test objects the output tracks the capacitance rise to hold the test voltage.

Knows what it is measuring

Capacitive objects show Cx and tan δ, inductive ones Lx and Q, and resistive ones Rx, with voltage, current, phase, power and frequency alongside. Units are chosen automatically.

Results on paper and in memory

The built-in thermal printer prints each result, automatically if you choose, and 100 results are stored with the date and time. An RS-232 port connects a computer.

Oil and materials too

Connect an oil cup to measure tan δ of insulating oil where the loss is 0.01% or more, or a solid-material electrode for insulation samples.

Specification

Technical specifications

TD-6900 Automatic Capacitance and Tan Delta Tester
High voltage output0.5 to 10 kV in 500 V steps (20 levels) · 1500 VA
Tan δ accuracy±(1.5% of reading + 0.06%)
Capacitance accuracy±(1.5% of reading + 5 pF)
ResolutionTan δ 0.001% · capacitance 0.001 pF
Tan δ range0.01% to 100%
Capacitance, internal HV3 pF to 60,000 pF at 10 kV · 60 pF to 1 µF at 0.5 kV
Capacitance, external HV3 pF to 1.5 µF at 10 kV · 60 pF to 30 µF at 0.5 kV
ConnectionsUST · GST · CVT self-excitation · reverse connection with low-voltage shielding (GSTg)
Test frequencySingle 45, 50, 55, 60 or 65 Hz · dual 50D (45/55 Hz) or 60D (55/65 Hz)
Standard capacitorInternal, or external with its parameters entered
External supplyTracks 40 to 70 Hz, including series resonant supplies
CVT ratio testRatio 10 to 99,999, ±1% of reading · phase 0 to 359.9°, ±0.1°
Harmonic adaptation≤3%
Oil testWith an oil cup, positive connection, for losses ≥0.01%
RecordsBacklit LCD · built-in thermal printer · 100 stored results with date and time · RS-232
Power supply220 V AC ±10% · 50/60 Hz ±1 Hz · mains or generator
Operating conditions−15°C to 50°C · relative humidity <80%
Dimensions / mass460 × 345 × 345 mm · 35 kg

What’s in the box

  • TD-6900 main unitWith built-in printer
  • Dedicated test cablesIncluding the CVT excitation lead
  • Mains lead and earth lead220 V AC
  • Spare printer paper and fuses5 A fuses
  • Operating manual and certificateIssue 1 manual

Need pricing or a spec check?

Tell us what you test and the voltage your procedure calls for.

REPLACES
GPS-6800

Using a GPS-6800?

The TD-6900 is now our tan delta tester and takes over from the GPS-6800. If you are moving test procedures or records across, talk to us and an engineer will help you set it up.

Before you order

Worth checking first

  • Supply. The TD-6900 runs on 220 V AC ±10%, 50/60 Hz, from the mains or a generator.
  • Above 10 kV. The built-in source reaches 10 kV. For higher test voltages, use an external supply and standard capacitor; tell us what you plan to pair it with.
  • Leads. Tell us the CVT or bushing types you test and we will confirm the leads supplied suit them.
Warranty & Downloads

Warranty, calibration & resources

Warranty & Service

USTGSTCVT self-excitationGSTg
Warranty: 1 year, subject to product registration.
Calibration: Certificate supplied. Recalibration recommended every year.
Service: Service and technical support for the life of the instrument.