CRT-600A Contact Resistance Meter

Substation & HV Asset Diagnostics

CRT-600A

600 A DC Contact Resistance Meter

Measures the contact and loop resistance of circuit breakers, switchgear and joints at up to 600 A DC, with a four-terminal connection that keeps lead resistance out of the result.

Supplied and supported by GPS LTD, London · 1-year warranty

CRT-600A contact resistance meter front panel
600 AMaximum DC test current
0.1 µΩResolution
0.5% ±2 dAccuracy
≈ 8 sTo a result on a fast test
Why the CRT-600A

High current. Micro-ohm precision.

A high test current gives a more representative reading of a contact under load, overcoming the surface films that can distort a low-current measurement.

01

Four test currents

Choose 100, 200, 300 or 600 A DC. The current comes from a constant-current switching supply that needs no manual adjustment, so every test starts the same way.

02

Four-terminal accuracy

Separate current and sense leads keep lead and clamp resistance out of the result. Readings resolve 0.1 µΩ with an accuracy of 0.5% ±2 digits.

03

Print and store

Print a result on the built-in printer or store it with the date and time. Settings and results read clearly on an English dot-matrix display.

How it connects

Four wires, one clear answer

Two thick leads carry the test current; two thin leads measure the voltage on the object itself, so only the resistance you want is measured.

Four-terminal connection: current leads on the outer ends of the test object, sense leads inside them
  1. Current leads on the outer ends. Thick red lead from I+ and thick black lead from I−, both on the same conductor, tightened firmly.
  2. Sense leads inside them. Thin red lead from V+ and thin black lead from V−, on the object just inside the current clamps.
  3. Clean, firm contact. Every clamp face clean and in good contact; red to red and black to black.
  4. Resistance between the sense points. That is the part of the joint or contact the reading describes.
How a test runs

From settings to a printed result

Four keys and one settings screen: choose the current and duration, start the test, and read the current and resistance together.

Settings screen with the test current highlighted
STEP 1

Set the current

Select steps through 100, 200, 300 and 600 A; OK confirms and moves on.

Settings screen with test highlighted, ready to start
STEP 2

Start the test

Choose the duration, highlight test and press OK.

Test in progress showing elapsed time and test current
STEP 3

Testing

The display shows the elapsed time and the test current as it is applied.

Result screen showing test current and resistance
STEP 4

Read, save, print

Current and resistance together. Store saves the result; Select prints it.

Where it is used

Wherever a contact has to carry current

Breakers, switchgear and busbars

Contact and loop resistance of high and low voltage circuit breakers, isolators and busbar runs.

Cable, weld and bolted joints

DC resistance of cable connections, welds and bolted joints that must carry high current.

Maintenance and commissioning

Routine substation maintenance and commissioning checks, with printed results for the record.

The panel

Everything on one face

CRT-600A front panel drawing with numbered callouts
  • 1Power input · AC220V terminals for the supply cord
  • 2Power switch · circuit breaker, ON / OFF
  • 3Earth terminal
  • 4Printer · prints the result
  • 5USB port
  • 6RS232 port
  • 7Display · 128 × 64 dot matrix
  • 8Keys · Reset, Select, OK, Store
  • 9I+ · current output
  • 10V+ · voltage sense
  • 11V− · voltage sense
  • 12I− · current output
Specification

CRT-600A at a glance

CRT-600A Contact Resistance Meter
Test currentDC 100 A, 200 A, 300 A, 600 A
Measurement range1 – 1999 µΩ
Range by test current0 – 50 mΩ (100 A) · 0 – 25 mΩ (200 A) · 0 – 16 mΩ (300 A) · 0 – 8 mΩ (600 A)
Resolution0.1 µΩ
Accuracy0.5% ±2 digits
MethodFour-terminal (Kelvin) connection, constant-current DC from a switching supply
Test durationFast · 30 s · 1 min · continuous
Test timeResult displayed in about 8 s (fast)
Display128 × 64 dot-matrix LCD, English
PrinterBuilt-in, prints the test result
DataClock and data storage
InterfacesUSB · RS232
TerminalsI+, I− current output · V+, V− voltage sense · earth terminal
Power6000 W
SupplyAC 220 V ±10%, 50 Hz · contact us to confirm the supply connection for your site
Working environment−10 °C to 40 °C · ≤80% RH, non-condensing
ShippingCarton 500 × 440 × 460 mm · 22 kg gross
CRT-600A in its aluminium carry case with the lid open

What’s in the box

  • CRT-600AIn its aluminium carry case
  • Test leadsThick current leads and thin voltage sense leads, red and black
  • Power cord
  • Earth lead
  • Printer paper

Need a quote?

Pricing, lead time and availability, usually within one working day.

Request a quote
Before you order

Good to know

  • Supply connection. The CRT-600A is rated AC 220 V ±10%, 50 Hz, 6000 W, connected on its power input terminals. Please contact us to confirm the supply connection for your site before ordering.
  • Shipping. 22 kg gross, in a carton of 500 × 440 × 460 mm.
  • Interfaces. USB and RS232 ports are fitted; ask us for details of their use.
  • Documentation. The quick start guide covers connection, testing, saving and printing. Full instructions for stored results and settings are available on request.
  • Ordering. Part number on request.
Support & downloads

Warranty, service & resources

Warranty & Service

Warranty: 1 year, subject to product registration.
Calibration: Calibration available from GPS. Please contact us for details.
Service: Service and repair by GPS LTD, London.